Conference Year

2021

Keywords

Rotary Compressor, Low Frequency Noise, Resonance, Numerical Calculation

Abstract

With the increasing speed and capacity of variable-speed rotary compressors, the problem of noise especially low and medium frequency noise in the air conditioning system which can't be solved by wrapping soundproof cotton has became more serious. In this paper, based on the noise problem of the rotor compressor with a working capacity of more than 80CC, the main frequency and the position of the noise source within 1000Hz are confirmed by simulation and experiment. Then on the base of this,the muffler and accumulator are respectively optimized and improved combining with Computer Aided Engineering (CAE) means. The final application results show that the optimized scheme can reduce noise by 6.1dB in 160Hz and 8.9dB in the frequency range of 500Hz to 800Hz, achieving good results.

Share

COinS