Groundwater intrusion into a building can cause serious structural degradation, corrosion of expensive mechanical equipment. ElectroOsmotic Pulse (EOP) technology is based on the concept of electroosmosis; the movement of an electrically charged ion in a liquid under the influence of an external electric field. EOP not only eliminates water-seepage problems from the interior of the structure without excavation, but it further mitigates corrosion damage to mechanical equipment and reduces the interior relative humidity of the basements.