Liquid flooded Ericsson cycle cooler

Jason J Hugenroth, Purdue University

Abstract

A novel approach to implementing a gas Ericsson cycle heat pump was developed. The concept, termed a liquid flooded Ericsson cooler (LFEC), uses liquid flooding of the compressor and expander to approach isothermal compression and expansion processes. Since the LFEC cycle has not been studied previously most of the work presented represents new contributions to the literature. The specific major contributions of the work can be summarized as follows. Analytical models of liquid flooded compression and expansion processes were developed, using ideal gas, constant specific heat, and incompressible liquid assumptions. Special considerations for fixed volume ratio positive displacement compressors are detailed. The unique behavior of a liquid flooded compressor was explored, including the discovery of an optimum liquid flooding rate that minimizes compression power. A computer model of the LFEC cycle was developed using ideal gas, incompressible liquid, and constant specific heat assumptions. The model was used for a thorough parameterc study. The purpose of the study was to explore the feasibility of the concept, identify the optimum operating parameters, and to provide the basis for the design of an experimental system. An experimental system was developed. It was believed to be the only system of its type in existence at the time of construction. Cooling capacities of up to 677 W were measured. Several factors related to the early state of development for the LFEC resulted in maximum second law efficiencies of only 3%. A second computer model of the LFEC was developed, which incorporated real fluid properties and additional parameters that were deemed necessary based on experimental observations. Two parametric studies were performed using this model. First, a parametric sensitivity study was performed to identify the minimum rotating machinery adiabatic efficiencies required to attain a COP of 1.25 for near ambient refrigeration applications. It was found that a well designed system with realistic losses could reach the target COP if the adiabatic efficiencies of the rotating machinery are equal or greater than 85%. The second parametric study, with the real fluid model, was used to identify the application (i.e. source temperature) for which the LFEC was most suited. It was found that when nonideal operation was assumed that the best second law efficiency for the LFEC occurs at source temperatures in the range of -90°C.

Degree

Ph.D.

Advisors

King, Purdue University.

Subject Area

Mechanical engineering

Off-Campus Purdue Users:
To access this dissertation, please log in to our
proxy server
.

Share

COinS