Performance analysis of EM-MPM and K-means clustering in 3D ultrasound breast image segmentation

Huanyi Yang, Purdue University

Abstract

Mammographic density is an important risk factor for breast cancer, detecting and screening at an early stage could help save lives. To analyze breast density distribution, a good segmentation algorithm is needed. In this thesis, we compared two popularly used segmentation algorithms, EM-MPM and K-means Clustering. We applied them on twenty cases of synthetic phantom ultrasound tomography (UST), and nine cases of clinical mammogram and UST images. From the synthetic phantom segmentation comparison we found that EM-MPM performs better than K-means Clustering on segmentation accuracy, because the segmentation result fits the ground truth data very well (with superior Tanimoto Coefficient and Parenchyma Percentage). The EM-MPM is able to use a Bayesian prior assumption, which takes advantage of the 3D structure and finds a better localized segmentation. EM-MPM performs significantly better for the highly dense tissue scattered within low density tissue and for volumes with low contrast between high and low density tissues. For the clinical mammogram, image segmentation comparison shows again that EMMPM outperforms K-means Clustering since it identifies the dense tissue more clearly and accurately than K-means. The superior EM-MPM results shown in this study presents a promising future application to the density proportion and potential cancer risk evaluation.

Degree

M.S.E.C.E.

Advisors

Christopher, Purdue University.

Subject Area

Electrical engineering|Medical imaging

Off-Campus Purdue Users:
To access this dissertation, please log in to our
proxy server
.

Share

COinS