Conference Year

2016

Keywords

vapor injection, bias angle of crankshaft, performance

Abstract

The offset angle of the upper and lower part of the crankshaft will affect the resistance of inspiration of high stage cylinder in the rotary two-stage inverter compressor with vapor injection, and then affect the performance. this paper presents the performance of the rotary two-stage inverter compressor with vapor injection in the bias angle of the crankshaft is calculated and compared with the experimental. The simulation results are in agreement with the experimental results. Under the operation of close vapor injection and open vapor injection, the performance of compressor can be improved 1% and 3% separately by optimize the bial angle of crankshaft. Â

Share

COinS